Site Loader

F – 80 Standard Test Methods for Fluid Resistance Of Gasket Materials. Designation: F – Standard Test Methods for. Fluid Resistance of Gasket Materials1 This standard is issued under the fixed designation F ; the. ASTM F – 04 Fluid Resistance of Gasket Materials This standard is issued under the fixed designation F ; the number immediately following the.

Author: Moogugrel Fauzragore
Country: Costa Rica
Language: English (Spanish)
Genre: Software
Published (Last): 2 June 2011
Pages: 255
PDF File Size: 20.75 Mb
ePub File Size: 6.84 Mb
ISBN: 286-1-79088-520-5
Downloads: 29849
Price: Free* [*Free Regsitration Required]
Uploader: Meztirg

Please copy and paste this embed script to where you want to embed Embed Script. The change in weight of the specimens is to be calculated as an expression of percentage change on the original weight. This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and if not revised, either reapproved or withdrawn.

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. The anvil shall have a diameter not less than that of the presser foot, which has a diameter of 6.

ASTM F146 – 12

Temperature of Test Measurement 7. The results f416 these test methods are not intended to give any direct correlation with service conditions in view of the wide variations in temperature and special uses encountered in gasket applications. These test methods are not applicable to the testing of vulcanized rubber, a procedure that is described in Test Method D Graduate the dial in 0.

Insert the aluminum-foil covered stoppers into the test tubes before placing them in the supporting rack within the oven.

ASTM F – 04 – Free Download PDF

Summary of Test Methods 3. Then withdraw the specimens from the cooled-down test fluid and immediately blot the samples f1466 sheets of blotting paper to remove excess liquid from the surfaces.

Link to Active This link will always route to the current Active version of the standard. Pour enough fresh fluid into the tube to completely cover satm specimens and ensure that they are immersed. Use the same sinker throughout. Thank you for interesting in our services.

  ASTM D1895 PDF

R146 care when removing the excess fluid so that no squeezing action occurs on the sample. These test methods are not applicable to the testing of vulcanized rubber, a procedure that is described in Test Method D It is designed for testing specimens cut from gasketing materials or from finished articles of commerce.

The producer must be aware that different coolant mixtures may yield different results. A superscript epsilon e indicates an editorial change since satm last revision or reapproval. The specific test fluids and test conditions outlined were selected as typical for purposes of comparing different materials and can t146 used as a routine test when agreed upon between the purchaser and the manufacturer. Your comments will receive careful consideration at a meeting of the responsible technical committee, which you may attend.

Your comments are invited either for revision of this standard or for additional standards and should be addressed to ASTM International Headquarters.

Please fill this form, we will try to respond as soon as possible. It is designed for testing specimens cut from gasketing materials or from finished articles of commerce. Size px x x x x Type 1 Class 2—A BA material, containing a normally lower swelling polymer.

Measure the weight of the test specimen to the nearest 1 mg 0. NOTE 1—Coolant mixtures are typically tested under boiling reflux conditions. Please help us to share our service with your friends. Use enough fluid to provide a minimum of 10 mL for each specimen in the container.

A number in parentheses indicates the year of last reapproval. The user should be aware that results may differ. The inch-pound units in parentheses are for information only. We need your help! The inch-pound units in parentheses are for information only. After immersing the specimens f1466 the various test fluids, the effect on physical properties is expressed as change in tensile strength, compressibility astmm softened condition, flexibility, volume change, and thickness and weight changes from the original condition.

  KRV POBJEDNIKA PDF

This gives the final volume, V2.

Originally approved in ASTM International atsm no position respecting the validity of any patent rights asserted in connection with any item mentioned in this standard. Last previous edition approved in as F — For materials having less than specific gravity 1.

Precision and Bias 7 Significance and Use 4.

There were six Type 1,7, three Type 3, and one Type 5 material evaluated for immersion weight change and thickness change in IRM oil. Historical Version s – view previous versions of standard. If such information is not asstm, then the material should be tested by itself t146 fresh fluid to determine compatibility with said fluid.

Take a sufficient number of readings, depending on the size of the specimen, to provide a reliable average value. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM F – 12 – Standard Test Methods for Fluid Resistance of Gasket Materials

It is understood that the results will be reported per D along with the specific immersion conditions used prior to said adhesion test. We need your help to maintenance this website. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, are entirely their own responsibility. Current edition approved April 1, The results of these test methods are not intended to give any direct correlation with service conditions in view of the wide variations in temperature and special uses encountered in gasket applications.